HOME

Hot - line:400-900-8812

Signal Conditioner Series

< >

Pressure sensor signal module

Industrial installation guide rail type, plug type terminal The built-in precision amplifying circuit, high precision Current voltage output provided at the same time, through the terminal arbitrary choice Suitable for weighing, torque, pressure and so on various strain bridge type sensor

Download
Guide rail type strain sensor signal module DPT
Industrial installation guide rail type, plug type terminal
The built-in precision amplifying circuit, high precision
Current voltage output provided at the same time, through the terminal arbitrary choice
Suitable for weighing, torque, pressure and so on various strain bridge type sensor
Suggest using single sensor
Furthest distance sensor transmitter walk line distance not more than 15 meters
For field need more sensors alone only transmitting, power distribution ark unified wiring installation

Technical parameters:

Input signal

The whole bridge strain sensor (weighing/measuring force sensor)

Unit

Input sensitivity

2.0±10% Special sensitivity (customizable)

mV/V

Load capacity

87 (4 350 ohm sensor)

Ω

Working power supply

12~26(0~5V output);18~26(0~10V及4~20mA output)

V DC

precision

0.1

%F.S.

Temperature characteristic

Better than 100

ppm

operating temperature

0~50



Size chart:

尺寸表: