Product description
Material          Stainless steel
Rated load      10kg~2t
Performance indicators
Accuracy          0.5%F.S
Sensitivity        0.6~1.2mv/v
Recommend excitation  5~10V DC(Recommend 10V)
Maximum excitation  12V DC
Cable          1.5m
Creep (30 minutes)  ±0.5%F.S
Zero Balance      ±1%F.S
Input impedance      350±20Ω
Output impedance      350±3Ω
Insulation Resistance      ≥5000MΩ
Using the environment parameter
Maximum safe overload      150%F.S
Ultimate overload      200%F.S
Operating Temperature      -20~+ 65℃
Temperature Effect On Zero  ±0.5%F.S/10oC
Temperature Effect On Load  ±0.5%F.S/10oC
Protection Class  IP65

Size chart: