Draw-Wire Transducer
Draw-wire transducer (encoder)
Measure Stroke: 2000,2500,3000,4000,5000mm Resolution: 1,0.5 mm / pulse Accuracy: +/- 0.1% (FS) +/- 1 pulse
DownloadDraw-wire transducer WED90
Range: 2000,2500,3000,4000,5000mm
Resolution: 1,0.5 mm / pulse
Accuracy: +/- 0.1% (FS) +/- 1 pulseDimensions:
ELECTRICAL CHARACTERISTICS:
Sensing element |
Incremental encoders
|
Working range |
2000,2500,3000,4000,5000mm
|
Resolution |
0.5 or 1 mm / pulse
|
Accuracy |
+/-0.1%FS
|
Output |
AB phase square wave, ABZ square wave
|
Circuit characteristics |
Voltage type, open collector, push-pull, linear differential
|
Operating Voltage |
12-24V DC/5V DC
|
Response frequency |
10K -50KHZ
|
Operating temperature |
-10 ~ +60°C
|
Storage temperature |
-20 ~ +80°C
|
Rope parameters |
0.7mm diameter plastic-coated steel cable
|
Pull rope speed |
1M/s
|
Impact |
10HZ to 1500HZ,10G
|
shock |
20G,11ms
|
Pull rope force |
900g
|
Signal cable |
Length 1M, diameter 5mm
|
Degree of protection |
IP65 (housing only)
|
WED90 |
Range | Resolution | Output | Circuit characteristics | Operating Voltage |
Optional: 2000/2500 / 3000/4000/5000mm |
1:1mm/pulse 05:0.5mm/pulse |
Blank: AB phase Z: ABZ phase |
Blank: voltage type C: Open collector PP: push-pull type L: linear differential |
blank: 12-24V DC 5V:5V |