Economical Glass Scale (Encoder)
Micro - position transducer grating
New design of improved products, better mechanical properties, more stable electrical characteristics! Electronics stroke: 10, 20, 30, 50, 75, 100 mm Resolution: 0.005mm, 0.01mm Output signal: 5V TTL square wave, long drive (differential), 24V NPN open collector Operating temperature: 0 - 40 ° C
DownloadNew design of improved products, better mechanical properties, more stable electrical characteristics!
Measurement length: 10, 20, 30, 50, 75, 100 mm
Resolution: 0.005mm, 0.01mm
Output signal: 5V TTL square wave, long drive (differential), 24V NPN open collector
Operating temperature: 0 - 40 ° C
FCT is a precision small grating measuring system suitable for precision measurement in small measuring ranges, especially for measuring, robotics, medical equipment, precision modern processing equipment. Usually used for continuous thickness measurement. FCT linear scale linear displacement changes into pulse signals.The number of pulse signals corresponding to the distance moved, the pulse frequency is a reaction speed. FCT The body consists of a set of precision linear plain bearings, return springs, glass gratings, LED lighting system components. FCT output signal is rectangular square wave. A, B phase 90 ° difference between the two-way waveform, can indicate the moving distance and direction.
FCT output signal (when moving to the inside of the scale)
Standard (no zero signal) Optional (with zero signal)
Wiring definition:
|
Long-term drive (standard) |
Long-term drive |
Long-term drive (standard) |
24V NPN Collector |
signal |
6-core cable |
8-core cable |
9 Pin CAN |
4-core cable |
+5 V |
Brown |
red |
1
|
Brown (+ 24V) |
0 V |
green |
blue |
2
|
green |
A phase |
White |
White |
3
|
White |
B phase |
yellow |
yellow |
4
|
yellow |
Z phase |
N/A |
gray |
5(N/A)
|
N/A |
Z invert |
N/A |
powder |
6(N/A)
|
N/A |
A is inverted |
gray |
Brown |
7
|
N/A |
B inversion |
powder |
green |
8
|
N/A |
shield |
silver |
silver |
9
|
silver |
Technical Features:
Measure the length | 10,,20,30,50,75,100 mm |
Resolution | 5µm ,10 µm |
Accuracy | ± 5µm |
Measure the speed | 0.25 m/s |
Operating force | 0.4-0.8N |
Operating Voltage | 5Vss ± 5%, 24V (optional) |
Current consumption (differential / TTL output) | max. 80 mA |
ConsumptionCurrent (OC Collector Open Output) | max. 60 mA |
Degree of protection | IP 40 |
Operating temperature | 0-40°C |
Dielectric strength | min. 20 M ohm |
Output current(Line Driver) | RS 422, 20 mA |
Output (TTL) |
L=max. 0.5V at< 10mA H=min. 3.5V at> 2.5mA |
Output (OC Collector Open) | Umax<30V,Imax<20mA |
Dimensions: (range 10,20,30,50 mm) Note: 10mm, 24V NPN open-collector output of the external dimensions and 20mm range consistent shape
Dimensions: (range 75,100 mm)
24V NPN Open Collector Circuit Features:
Grating signal commonly used acquisition method:
1. Grating digital display table:Single axis/Two-axis / three-axis
2. Connect PLC high-speed counter (need to order 24V NPN open-collector signal output scale)
3. Connect PLC high-speed counting module (5V TTL or 5V differential signal input)
4. With the quadruple frequency function of the computer counting boardJJX-6000 (PCI interface, serial communication)