Economical Glass Scale (Encoder)
Micro - position probe grating
Measuring length: 10mm Resolution: 0.005mm Output signal: 5V TTL square wave, 24V HTL Operating temperature: 0 - 40 ° C
Download
Displacement Probe Grating
Measuring length: 10mm
Resolution: 0.005mm
FCSS is a precision small grating measuring system suitable for small-scale precision measurement, especially for measuring, robotics, medical equipment, precision modern processing equipment. Usually used for continuous thickness measurement. FCSS linear scale linear displacement changes into pulse signals.The number of pulse signals corresponding to the distance moved, the pulse frequency is a reaction speed. FCSS The body consists of a set of precision linear plain bearings, return springs, glass gratings, LED lighting system components. Signal circuit external (cable type signal converter)
The FCSS output signal is a rectangular square wave. A, B phase difference of 90 ° of the two waveforms, can indicate the moving distance and direction
Measuring length: 10mm
Resolution: 0.005mm
Output signal: 5V TTL square wave, 24V HTL
Operating temperature: 0 - 40 ° CFCSS is a precision small grating measuring system suitable for small-scale precision measurement, especially for measuring, robotics, medical equipment, precision modern processing equipment. Usually used for continuous thickness measurement. FCSS linear scale linear displacement changes into pulse signals.The number of pulse signals corresponding to the distance moved, the pulse frequency is a reaction speed. FCSS The body consists of a set of precision linear plain bearings, return springs, glass gratings, LED lighting system components. Signal circuit external (cable type signal converter)
The FCSS output signal is a rectangular square wave. A, B phase difference of 90 ° of the two waveforms, can indicate the moving distance and direction
FCSS Output signal (when moving to the inside of the scale) | |||||||||||||||||||||||||||||||||||||
TTL output
|
Linear differential output
|
||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||
Connection cable and connector definition: | |||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||
Technical Features: |
|||||||||||||||||||||||||||||||||||||
|
Dimensions:
Grating signal commonly used acquisition method:
1. Grating digital display table:Single axis Two-axis / three-axis
2. Direct connection of PLC high-speed counting module (5V TTL or 5V differential signal input)
3. With four multiplier function of the computer counting board